Author Takeda, Yoshimasa| Kawashima, Takahisa| Kiyota, Kazuya| Oda, Shigeto| Morimoto, Naoki| Kobata, Hitoshi| Isobe, Hisashi| Honda, Mitsuru| Fujimi, Satoshi| Onda, Jun| I, Seishi| Sakamoto, Tetsuya| Ishikawa, Masami| Nakano, Hiroshi| Sadamitsu, Daikai| Kishikawa, Masanobu| Kinoshita, Kosaku| Yokoyama, Tomoharu| Harada, Masahiro| Kitaura, Michio| Ichihara, Kiyoshi| Hashimoto, Hiroshi| Tsuji, Hidekazu| Yorifuji, Takashi| Nagano, Osamu| Katayama, Hiroshi| Ujike, Yoshihito| Morita, Kiyoshi|
Published Date 2014-12
Publication Title Resuscitation
Volume volume85
Issue issue12
Content Type Journal Article
JaLCDOI 10.18926/AMO/53021
FullText URL 68_6_323.pdf
Author Hirayama, Takahiro| Nagano, Osamu| Shiba, Naoki| Yumoto, Tetsuya| Sato, Keiji| Terado, Michihisa| Ugawa, Toyomu| Ichiba, Shingo| Ujike, Yoshihito|
Abstract In adult high-frequency oscillatory ventilation (HFOV), stroke volume (SV) and mean lung pressure (PLung) are important for lung protection. We measured the airway pressure at the Y-piece and the lung pressure during HFOV using a lung model and HFOV ventilators for adults (R100 and 3100B). The lung model was made of a 20-liter, airtight rigid plastic container (adiabatic compliance: 19.3ml/cmH<sub>2</sub>O) with or without a resistor (20cmH<sub>2</sub>O/l/sec). The ventilator settings were as follows: mean airway pressure (MAP), 30cmH2O;frequency, 5-15Hz (every 1Hz);airway pressure amplitude (AMP), maximum;and % of inspiratory time (IT), 50% for R100, 33% or 50% for 3100B. The measurements were also performed with an AMP of 2/3 or 1/3 maximum at 5, 10 and 15Hz. The PLung and the measured MAP were not consistently identical to the setting MAP in either ventilator, and decreasing IT decreased the PLung in 3100B. In conclusion, we must pay attention to the possible discrepancy between the PLung and the setting MAP during adult HFOV.
Keywords HFOV mean lung pressure mean airway pressure
Amo Type Original Article
Published Date 2014-12
Publication Title Acta Medica Okayama
Volume volume68
Issue issue6
Publisher Okayama University Medical School
Start Page 323
End Page 329
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language 英語
Copyright Holders CopyrightⒸ 2014 by Okayama University Medical School
File Version publisher
Refereed True
PubMed ID 25519026
Web of Science KeyUT 000346882200002
Related Url http://ousar.lib.okayama-u.ac.jp/metadata/53132
JaLCDOI 10.18926/AMO/48688
FullText URL 66_4_335.pdf
Author Shiba, Naoki| Nagano, Osamu| Hirayama, Takahiro| Ichiba, Shingo| Ujike, Yoshihito|
Abstract In adult high-frequency oscillatory ventilation (HFOV) with an R100 artificial ventilator, exhaled gas from patientʼs lung may warm the temperature probe and thereby disturb the humidification of base flow (BF) gas. We measured the humidity of BF gas during HFOV with frequencies of 6, 8 and 10Hz, maximum stroke volumes (SV) of 285, 205, and 160ml at the respective frequencies, and, BFs of 20, 30, 40l/min using an original lung model. The R100 device was equipped with a heated humidifier, HummaxⅡ, consisting of a porous hollow fiber in circuit. A 50-cm length of circuit was added between temperature probe (located at 50cm proximal from Y-piece) and the hollow fiber. The lung model was made of a plastic container and a circuit equipped with another HummaxⅡ. The lung model temperature was controlled at 37℃. The HummaxⅡ of the R100 was inactivated in study-1 and was set at 35℃ or 37℃ in study-2. The humidity was measured at the distal end of the added circuit in study-1 and at the proximal end in study-2. In study-1, humidity was detected at 6Hz (SV 285ml) and BF 20l/min, indicating the direct reach of the exhaled gas from the lung model to the temperature probe. In study-2 the absolute humidity of the BF gas decreased by increasing SV and by increasing BF and it was low with setting of 35℃. In this study setting, increasing the SV induced significant reduction of humidification of the BF gas during HFOV with R100.
Keywords HFOV humidification
Amo Type Original Article
Published Date 2012-08
Publication Title Acta Medica Okayama
Volume volume66
Issue issue4
Publisher Okayama University Medical School
Start Page 335
End Page 341
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language 英語
Copyright Holders CopyrightⒸ 2012 by Okayama University Medical School
File Version publisher
Refereed True
PubMed ID 22918206
Web of Science KeyUT 000307918900006