Author Kinami, Yo| Noda, Tomoyuki| Ozaki, Toshifumi|
Published Date 2013-05
Publication Title Journal of Orthopaedic Science
Volume volume18
Issue issue3
Content Type Journal Article
Author Shimamura, Yasunori| Inoue, Madoka| Ozawa, Masatugu| Kanazawa, Tomoko| Saitou, Taiichi| Nakahara, Ryuichi| Noda, Tomoyuki| Nishida, Keiichiro| Ozaki, Toshifumi|
Published Date 2011-08-01
Publication Title 岡山医学会雑誌
Volume volume123
Issue issue2
Content Type Journal Article
Title Alternative Japanese guidelines for the treatment of hip fractures in the elderly
FullText URL 122_253.pdf
Author Noda, Tomoyuki| Ozaki, Toshifumi|
Publication Title 岡山医学会雑誌
Published Date 2010-12-01
Volume volume122
Issue issue3
Start Page 253
End Page 257
ISSN 0030-1558
language 日本語
Copyright Holders Copyright (c) 2010 岡山医学会
File Version publisher
DOI 10.4044/joma.122.253
NAID 130004903185
JaLCDOI 10.18926/AMO/32855
FullText URL fulltext.pdf
Author Shimamura, Yasunori| Nishida, Keiichiro| Imatani, Junya| Noda, Tomoyuki| Hashizume, Hiroyuki| Ohtsuka, Aiji| Ozaki, Toshifumi|
Abstract <p>We biomechanically evaluated the bone fixation rigidity of an ONI plate (Group I) during fixation of experimentally created transcondylar humerus fractures in cadaveric elbows, which are the most frequently observed humeral fractures in the elderly, and compared it with the rigidity achieved by 3 conventional fixation methods:an LCP reconstruction plate 3.5 using a locking mechanism (Group II), a conventional reconstruction plate 3.5 (CRP) with a cannulated cancellous screw (Group III), and a CRP with 2 cannulated cancellous screws (CS) in a crisscross orientation (Group IV). In the axial loading test, the mean failure loads were:Group I, 98.9+/-32.6;Group II, 108.5+/-27.2;Group III, 50.0+/-7.5;and Group IV, 34.5+/-12.2 (N). Group I fixations failed at a significantly higher load than those of Groups III and IV (p0.05). In the extension loading test, the mean failure loads were:Group I, 34.0+/-12.4;Group II, 51.0+/-14.8;Group III, 19.3+/-6.0;and Group IV, 14.7+/-3.1 (N). Group IV fixations showed a significantly lower failure load than those of Group I (p0.05). The fixation rigidities against mechanical loading by the ONI plate and LCP plate were comparable. These results suggested that an ONI system might be superior to the CRP and CS method, and comparable to the LCP method in terms of fixation rigidity for distal humerus fractures.</p>
Keywords distal humerus fracture biomechanics internal fixation elderly
Amo Type Original Article
Published Date 2010-04
Publication Title Acta Medica Okayama
Volume volume64
Issue issue2
Publisher Okayama University Medical School
Start Page 115
End Page 120
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language 英語
File Version publisher
Refereed True
PubMed ID 20424666
Web of Sience KeyUT 000276996900005
JaLCDOI 10.18926/AMO/32853
FullText URL fulltext.pdf
Author Endo, Hirosuke| Noda, Tomoyuki| Mitani, Shigeru| Nakahara, Ryuichi| Tetsunaga, Tomonori| Kunisada, Toshiyuki| Ozaki, Toshifumi|
Abstract <p>Femoroacetabular impingement (FAI) is a condition characterized by the impingement of the femur and acetabulum. In Japan, this disorder has become recognized gradually. Here we report a rare case of surgically treated FAI, associated with an osseous protrusion on the acetabulum of a 30-year-old female. Plain computed tomography (CT) and reconstructive 3D-CT images clearly demonstrated an anterolateral bony protrusion. Hip arthroscopy showed no degeneration of the cartilage on either the femoral or acetabular side, but degeneration at the edge of labrum was observed in the region of the bony protrusion. The complete removal of the bony protrusion under hip arthroscopy was thus considered impracticable, and a small skin incision was therefore made anteriorly to approach the acetabulum. The Short-Form 36-Item Health Survey (SF-36) revealed improvement in all scores.</p>
Keywords femoroacetabular impingement bony protrusion Pincer type hip arthroscopy SF36
Amo Type Case Report
Published Date 2010-04
Publication Title Acta Medica Okayama
Volume volume64
Issue issue2
Publisher Okayama University Medical School
Start Page 149
End Page 154
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language 英語
File Version publisher
Refereed True
PubMed ID 20424671
Web of Sience KeyUT 000276996900010
JaLCDOI 10.18926/AMO/30972
FullText URL fulltext.pdf
Author Endo, Hirosuke| Asaumi, Koji| Mitani, Shigeru| Noda, Tomoyuki| Minagawa, Hiroshi| Tetsunaga, Tomonori| Ozaki, Toshifumi|
Abstract <p>A minimally invasive plate osteosynthesis technique using a locking compression plate (LCP) has been used widely in trauma cases. Its advantages are that the MIPO technique does not interfere with the fracture site and thus provides improved biological healing, and that the LCP has excellent angular stability. Its use in bone lengthening, however, has not been established. In such cases, it is desirable to shorten the external skeletal fixation period as much as possible. Here, the MIPO technique using an LCP was applied to femoral distraction osteogenesis in an attempt to shorten the external skeletal fixation period. For femoral lengthening, the MIPO technique was performed in 2 stages. Orthofix external fixators (Orthofix, England) were used to insert screws from the anterolateral side rather than from the lateral side of the femur for bone lengthening. When sufficient callus formation was detected postoperatively at the site of bone lengthening, and the absence of infection was ensured, limb draping was performed, including a whole external fixator, and then the MIPO technique was applied with an LCP. In 3 cases (5 limbs), the average duration of external skeletal fixation was 134days, the average external-fixation index was 24days/cm, and the average consolidation index was 22days/cm. The MIPO technique using an LCP made it possible to shorten the external skeletal fixation-wearing period in femoral lengthening.</p>
Keywords femoral lengthening minimally invasive plate osteosynthesis locking compression plate external skeletal fixation external-fixation index
Amo Type Original Article
Published Date 2008-10
Publication Title Acta Medica Okayama
Volume volume62
Issue issue5
Publisher Okayama University Medical School
Start Page 333
End Page 339
ISSN 0386-300X
NCID AA00508441
Content Type Journal Article
language 英語
File Version publisher
Refereed True
PubMed ID 18985094
Web of Sience KeyUT 000260391300008
Author 野田 知之|
Published Date 2000-09-30
Publication Title
Content Type Thesis or Dissertation